Contents | « Previous | 🎲 Random topic | Next »

CARDIOLOGY - ECG LIBRARY


Case 4

70M with syncope, GCS 12, BP 70/40. Pale and sweaty

Expected Response

Complete heart block (1 mark)
Broad complex QRS – ventricular escape [bigeminy] (1 mark)
Vent rate approx. 40/min (1 mark)
Atrial rate approx. 100/min (1 mark)
AV dissociation (1 mark)